2 results
Evaluation of Paramedic Utilization of the Intubating Laryngeal Mask Airway in High-Fidelity Simulated Critical Care Scenarios
- Donald Byars, Bruce Lo, Jeff Yates
-
- Journal:
- Prehospital and Disaster Medicine / Volume 28 / Issue 6 / December 2013
- Published online by Cambridge University Press:
- 04 September 2013, pp. 630-631
- Print publication:
- December 2013
-
- Article
- Export citation
-
Introduction
Successful oxygenation and ventilation can mean the difference between life and death in the prehospital setting. While airway challenges can be numerous within the confines of the emergency department, there are many additional confounding difficulties in the prehospital setting, which include limited access to equipment, poor lighting, extreme environments, limited personnel to assist, no immediate backup, and limited rescue airway options. The concept of an easy, reliable, and rapidly deployable alternative rescue airway device is critical, especially when considering the addition of rapid sequence intubation protocols in the prehospital setting.
HypothesisThe primary objective of this study was to ascertain whether paramedics can be trained to deploy this alternative airway device with an acceptable success rate in a simulated critical care airway scenario. The secondary objective was to determine whether the previously-trained paramedics were able to retain their ability to deploy the device successfully at one year.
MethodsThis was a prospective, observational, single-group, descriptive cohort, educational trial. Forty paramedics were trained in the use of the Intubating Laryngeal Mask Airway (I-LMA) in a simulation medicine curriculum culminating in a simulated critical care difficult airway scenario requiring urgent oxygenation and ventilation after failed traditional endotracheal intubation. An emergency medicine physician proctor determined successful airway management. Repeat testing was then performed at approximately one year out, challenging the medics to intubate a mannequin using the I-LMA during an unrelated training session.
ResultsOf the 40 paramedics who underwent complete simulation training, 39 were able to intubate and ventilate the simulated difficult airway using the I-LMA during the critical care scenario. This yields a success rate of 97.5% (95% CI, 87.1%-99.4%). At approximately one year out, 35 out of 35 medics were able to intubate the mannequin using the I-LMA, resulting in a success rate of 100% (95% CI, 91.4%-100%).
ConclusionsIn this study, paramedics were able to deploy the I-LMA with a high degree of success in a simulated difficult airway, with a high degree of skill retention at one year out.
. ,Byars D ,Lo B .Yates J Evaluation of Paramedic Utilization of the Intubating Laryngeal Mask Airway in High-Fidelity Simulated Critical Care Scenarios . Prehosp Disaster Med.2013 ;28 (6 ):1 -2
Evaluation of Success Rate and Access Time for an Adult Sternal Intraosseous Device Deployed in the Prehospital Setting
- Donald V. Byars, Sara N. Tsuchitani, Eleanor Erwin, Bradley Anglemyer, Jacob Eastman
-
- Journal:
- Prehospital and Disaster Medicine / Volume 26 / Issue 2 / April 2011
- Published online by Cambridge University Press:
- 03 May 2011, pp. 127-129
- Print publication:
- April 2011
-
- Article
- Export citation
-
Introduction: Access to the vascular system of the critically ill or injured adult patient is essential for resuscitation. Whether due to trauma or disease, vascular collapse may delay or preclude even experienced medical providers from obtaining standard intravenous (IV) access. Access to the highly vascular intramedullary space of long bones provides a direct link to central circulation. The sternum is a thin bone easily identified by external landmarks that contains well-vascularized marrow. The intraosseous (IO) route rapidly and reliably delivers fluids, blood products, and medications. Resuscitation fluids administered by IV or IO achieve similar transit times to central circulation. The FAST-1 Intraosseous Infusion System is the first FDA-approved mechanical sternal IO device. The objectives of this study were to: (1) determine the success rate of FAST-1 sternal IO device deployment in the prehospital setting; (2) compare the time of successful sternal IO device placement to published data regarding time to IV access; and (3) describe immediate complications of sternal IO use.
Methods: All paramedics in the City of Portsmouth, Virginia were trained to correctly deploy the FAST-1 sternal IO device during a mandatory education session with the study investigators. The study subjects were critically ill or injured adult patients in cardiac arrest treated by paramedics during a one-year period. When a patient was identified as meeting study criteria, the paramedic initiated standard protocols; the FAST-1 sternal IO was substituted for the peripheral IV to establish vascular access. Time to deployment was measured and successful placement was defined as insertion of the needle, with subsequent aspiration and fluid flow without infiltration.
Results: Over the one-year period, paramedics attempted 41 FAST-1 insertions in the pre-hospital setting. Thirty (73%) of these were placed successfully. The mean time to successful placement was 67 seconds for 28 attempts; three of the 31 insertions did not have times recorded by the paramedic. Paramedics listed the problems with FAST-1 insertion, including: (1) difficulty with adhesive after device placement (3 events); (2) failure of needles to retract and operator had to pull the device out of the skin (2 events); and (3) slow flow (1 event). Emergency department physicians noted two events of minor bleeding around the site of device placement.
Conclusion: This is the first study to prospectively evaluate the prehospital use of the FAST-1 sternal IO as a first-line device to obtain vascular access in the critically ill or injured patient. The FAST-1 sternal IO device can be a valuable tool in the paramedic arsenal for the treatment of the critically ill or injured patient. The device may be of particular interest to specialty disaster teams that deploy in austere environments.